Terralux DR10 Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 5
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
!
!
/!
TerraLUX D
R
10 Product Specification – Subject to change without notice
!
WWW.TERRALUX.COM
10/01/2014
!
automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense
®
regularly measures the operating temperature
and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70@60,000 hour lumen
maintenance curves. LEDSense
®
is always active, and will compensate for variation in thermal
conditions due to heatsinking, ambient air, Engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense
®
Power Curve identifies the
reduction in input power over temperature.
Przeglądanie stron 2
1 2 3 4 5

Komentarze do niniejszej Instrukcji

Brak uwag